JMT -
601 |
PLASTIC LIMIT SET IS : 2720
(Part – VII)
ASTM D 427, BS : 1377 AASHO 190.
Moisture contents at which soil as smallest plasticity is called limit.
For determination purpose plastic limit is defied as the water content
at which a soil will just begin to crumble when rolled into a thread of
3mm. dia.
Specifications: The complete set consists of one each: -
Glass plate 20cm x 115cm having ground ends and one side frosted.
Brass or stainless steel rod 3 mm dia x 150mm long.
1. Flexible spatula.
2. Set of 6 moisture containers.
3. Porcelaine basin 150mm dia.
4. Plastic wash bottle 500 ml.. |
|
 |
| |
|
|
|
|
| |
JMT -
602 |
SHRINKAGE LIMIT SET IS : 2720 (Part – VII)
ASTM D 427, BS : 1377, AASHO T 92.
Shrinkage limit is the maximum water content at which a reduction in
water content does not cause an appreciable reduction in volume of the
soil mass. At shrinkage limit, on further reduction in water, air enters
into the voids of soils and thus keeps the volume constant.
The apparatus can be used to determine shrinkage limit and to calculate
other shrinkage factors like shrinkage ratio, shrinkage index and
volumetric shrinkage.
Specification: Set consists of one each: -
1.Porcelain evaporating Dish
2. Shrinkage Dish
3. Glass cup
4. Perspex plate with three metal prongs
5. Perspex plate.
6.Flexible spatula
7. Glass cylinder 25ml x 0.5 ml. supplied without mercury.
Optional accessories: Mercury supplied in bottle of 500 gms.
.
|
|
 |
| |
|
|
|
|
| |
JMT -
603 |
CONE
PENETROMETER IS :2720 (Part V)
For determining the Liquid Limit of soils. This is specially useful to
obtain reliable and accurate results for those soils which have low
plasticity index. The percentage moisture contents determined when cone
with half angle of 15-30 minutes under a total sliding weight of 148 gm
penetrates 25 mm gives the Liquid Limit.
. |
|
 |
| |
|
|
|
|
| |
JMT -
604 |
HIGH
SPEED STIRRER IS : (Part IV).
This is for mechanical analysis and also other laboratory applications
for stirring. Speed approximately 4000 rpm under load. A dispersion cup
is supported on a rest on the stand of the stirrer and has a removable
baffle. For operation on 230-250 volts A.C. supplied without dispersion
cup or baffle. |
|
 |
| |
|
|
|
|
| |
JMT -
605 |
LIQUID
LIMIT DEVICE
IS : 2720(Part V), IS : 9259,BS : 1377, AS : 89.
Casagrande method is mechanical form is known as Liquid Limit method and
has been in use for still mechanics for a number of years. The liquid
limit data of soils is useful to correlate mechanical properties of
soil, such as compressibility and lower shear strength. Liquid limit is
the water content at which soil passes from zero strength to an
infinitesimal strength, hence the true value of liquid limit cannot be
determined. For determination purpose liquid limit is that water content
at which part of soil, cut by a groove of standard dimensions, will flow
together for a distance of 1.25cm under an impact of 25 blows in a
standard liquid limit apparatus. The soil at the water content has some
strength, which is about 0.17N/cm.sq. (17gms/sq.cm.) At this water
content soil just passes from liquid state to plastic state.
Specifications: It consists os a brass cup held on an adjustable
bracket. The cup can be adjusted for a fall of 1 cm and can be raised
and dropped on a rubber base of standard hardness by cam action.
Complete with one casagrande grooving tool, one ASTM Grooving tool and a
high gauge block (Type A of IS 9259). |
|
 |
| |
|
|
|
|
| |
JMT -
606 |
LIQUID
LIMIT DEVICE (WITH COUNTER)
Same as above but fitted with a counter to register the umber of blows.
. |
|
 |
| |
|
|
|
|
| |
JMT -
607 |
LIQUID
LIMIT DEVICE (MOTORISED)
Same as above but fitted with a motor geared down to give approximately
120r.p.m. suitable for operation on 230 volts, single phase, 50 cycles,
A.C. supply.
Spares: Casagrande grooving tool. ASTM Grooving tool, Height block, 1cm
high. |
|
 |
| |
|
|
|
|
| |
JMT -
608 |
GRAIN
SIZE ANALYSIS (PIPETTE METHOD)
IS: 2720(part - IV) and BS : 1377.
This is
for the determination of there sub sieve particle distribution in a soil
sample by mechanical analysis. An analysis of this kind expresses
quantitatively the proportions by weight of the various sizes of
particles present in the soil. It is recommended as a standard procedure
to use dispersion agent to avoid flectuation.
Specification: The apparatus consists of a sliding panel which moves up
and down by means of a screw allowing Anderson pipette fixed to it to be
raised or lowered vertically. A sedimentation tube is held by a
laboratory clamp provided on the stand below the pipette . The depth of
immersion is measured by a scale graduated in mm at the side of the
sliding panel. Supplied complete with Aderson pipette 10ml. at the side
capacity made from glass, and a sedimentation tube also of glass of 500
ml capacity and 50 Nos. Test forms.
. |
|
 |
| |
|
|
|
|
| |
JMT -
609 |
PLUMMET
BALANCE
Conventionally particle size distribution analysis is carried out using
pipette and hydrometer methods. Whereas in hydrometer method it is
possible to determine particle sizes in the range 75 microns, the method
involves computation and it is time consuming. The pipette method can be
used for determining only the percentage of specific sizes less than
0.02, 0.006 and 0.002mm as a percentage of total soil sample. The
plummet balance method to determine sub sieve particle size for the
entire range is very rapid and only manipulation of height of the
balance, so that plummet sinks to the right depth is required. The
percentage of soil in suspension is directly indicated by a pointer over
a graduated scale.
Specification: A vertical rod is mounted on a sturdy base having
leveling screws. A pointer with steel pivots turns in jewel bearing and
moves over a graduated scale. Scale graduations are made 0-100% x 2%.
To the ogher end of the pointer a plummet is hanged. Rack and pinion
arrangement is provided on the vertical rod for adjusting the height.
Supplied with a chart showing relationship between "K" and temperature
of suspension of soils of varing specific gravity from 2.4 to 2.8 to
help in solving stroke’s equation. Supplied complete with one Perspex
plummet one measuring jar and one rider weight for zero adjustment and
one rider weight for adjusting the pointer to 100%..
. |
|
 |
| |
|
|
|
|
| |
JMT -
610 |
MARSH
CONE
This cone is used to find out Viscosity of Bentinite slurry and like
material. The Marsh Cone is 6 inch in diameter at the top and 12inch
ling, and tapers to join a tube 2 inch long and 3/16 inch inside dia.
The capacity of the funnel is 1500 cc.. Time in seconds required to flow
out 1000cc of slurry from cone is measured as funnel viscosity of the
material. |
|
 |
| |
|
|
|
|
| |
|
Next |
|
|
| |
|
|
|
|
| |
Bitumen |
Asphalt |
Aggregate |
Cement Concrete |
Soil |