JMT -
501 |
CEMENT
SAMPLER
IS : 7535 - 1986
This is a brass tube approximately 53cm long and 2.8cm I.D. with a
wooden handle. Total length approximately 73cm. The tube has the sharp
angular with conveniently pierces cement bags. An air hole of
approximately 3mm dia is drilled on the tube near handle. Total sample
collected at one time is 300cm 3 approximately. . |
|
 |
| |
|
|
|
|
| |
JMT -
502 |
BLAINE'S AIR PERMEABILITY APPARATUS
IS : 4031,5516,1727 AND 4828, ASTM C-204, BS : 4359 PART II
The apparatus is used for determining the fineness of cement in terms of
specific surface expressed as total surface area in square centimeters
per gram of cement. This is a variable flow type air permeameter.
Specifications : The apparatus consists one each of permeability cell
12.5mm I.D., Manometer 'U' type mounted on stand with a built in a stop
cock, perforated disk, plunger Rubber stopper, Rubber tube 30cm long.
Packet of 12 filter paper discs and a bottle of 100cc dibutyiphthalate
liquid.
Spares and Accessories : Punch to cut filter paper discs.Non-performed
disc. Suction bulb.
|
|
 |
| |
|
|
|
|
| |
JMT -
503 |
VICAT
NEEDLE APPRATUS WITH DASHPOT
Same as above but in addition is fitted with a dash pot which facilities
gentle lovering of the needles.
Accessories : Mild steel base plate 5inches x 5inches.Fulcrum
muld, brass, 70mm I.D base dia x 60mm I.D> top dia, 40mm height.
Note : 1) Normally set of needles and mould which meet IS requirements
as per IS.5513 are supplied. While ordering please specify the
specifications code of the instrument required.
2) vicat needle apparatus for determining consistency of Hydraulic
cement, gypsum plaster, lime etc. as per ASTM C 187-58, c 472-62: c
110-58, IS 2542 (part-i) can be also supplied. |
|
 |
| |
|
|
|
|
| |
JMT -
504 |
VICAT
NEEDLE APPARATUS
IS : 4031, 2645, 2542, (PART-i ), 1727, 5513 & 712. BS : 12, 146, 915,
1370, 4027, 4246, 4248. AASHO - T 129, E 131.
This instrument is used for determining the normal consistency and
settings times of cement and 'A' class limes.
Specifications : The apparatus consists of of a metallica frame bearing
a freely mocable rod with a cap at top, one vicat mould, split type and
glass base plate and one set of needles one each initial needle, final
needle and consistency plunger.. |
|
|
| |
|
|
|
|
| |
JMT -
505 |
AIR
PERMEABILITY APPRATUS(RIGDEN TYPE)
IS : 8425, BS : 4352 PART-II, BS : 12,146, 915, 1370,4027, 4246 & 4248
Comprises one air permeability cell of range 500 to 10000 sq.cm/gm. The
cell is complete with a perforated disc and a compacting plunger. The
instrument is supplied with 'U'. Tube manometer having an isolation tap
assembly and a suction blub., This apparatus is mounted in a woolen
cabinet.. |
|
|
| |
|
|
|
|
| |
JMT -
506 |
LEA
AND NURSE AIR PERMEABILITY APPARATUS
IS : 5536, 8425, BS : 12, 1370, 146 & 915.
The meatheod and results obtained from this apparatus depend upon the
rate at which air flows under a given pressure gradient through a bed
powder of known density and voids content, in order to determine the
surface area of the individual particles.
Specifications : The complete equipment comprises of one air
permeability cell lea and nurse type for areas 500 to 10000 sq.cm/gm.
complete with perforated plate one capillary tube, one plunger for
compaction of sample and a wooden case.
Accessions : Air source, comprising one pressure chamber fitted
with a value, regulator, connecting tube, a toot pump and two drying
towers. Manometer liquid in 500ml bottles. |
|
|
| |
|
|
|
|
| |
JMT -
507 |
LE
CHATELIER FLASK
IS : 4031 - 1968.
Used for finding specific gravity of Hydraulic cement. Made from brosill
glass. The flask is 243mm in total height, having a buld of 90mm dia of
25ml approximate capacity. The long neck of the flask has at a top
funnel of 50mm dia in which fits a ground glass stoper. The neck has
over all 11 I.D. Upper portionis graduated from 18 ml to 24 ml with .1
ml graduation. Just at the bottom of the nek 1ml capacity is marked in
between there is 17ml capacity bulb. |
|
 |
| |
|
|
|
|
| |
JMT -
508 |
GILLMORE NEEDLE APPARATUS
ASTM-C 191
This instrument is used for determining the time setting of hydraulic
cement.
Specifications : A base with a vertical shaft and two horizontal arms.
The lower arm is adjustable for height. 1 No. initial needle 1/12inch
dia 1/4ld.wt. 1 No. Final needle 1/12inch dia. 1lb.wt. 1 No. glass base
plate. Complete as above. |
|
 |
| |
|
|
|
|
| |
JMT -
509 |
KENLLEY BALL PENETRATION APPARATUS
ASTM C-360
The apparatus is used to determine the workability of portland cement
concrete. The kelly ball test is considered to be simple and much faster
than the slump test. Twice the kelly ball reading approximately equals
the slump.
Specifications : It consists of a cylinder with a ball -shaped bottom
and handle, together weighing 15 kg. A strip frame, guides the handle
and serves as a reference of measuring the depth of penetration. The
handle is graduated in MM. Penetration can be recorded to the nearest
0.5mm.
. |
|
 |
| |
|
|
|
|
| |
JMT -
510 |
LE
CHATELIER MOULD
IS : 269, 712, 5514, 1727, 2645,4031, 6932(PART-IX) BS : 890, 915, 1370,
4027,4226 & 4248.
It is used for teh determination of soundness by expansion meatheod of
ordinary and rapid hardneing portland cement, low heat portland cement
and class A lines.
Specifications : It consists of a small split cylinder forming a mould.
On either side of the split cylinder, two parallel indicating arms with
pointed ends are attached. Supplied complete with two glass plates and a
lead weight. |
|
|
| |
|
|
|
|
| |
|