JMT -
101 |
RING
AND BALL APPARATUS IS: 1205 - 1985, IP : 58/63
The apparatus is used to determine softening point of bitumen. Ring and
ball apparatus is used to determine softening point. It is that
temperature at which a sample of bituminous material loaded by a 9.5mm
dia-steel ball, drops at the distance of 25mm.
Specifications : The apparatus consists of steel braket with a sliding
plate support. That supports has two holes of 10mm dia on which a Ring
and Ball guide can be kept. A central hole on this plate is for
inserting thermometer. Supplied with a glass beaker approximate 8.5c.m.
I.D., 12 cm high and a hand stirrer and nos. 9.5mm dia steel balls. |
|
 |
| |
|
|
|
|
| |
JMT -
102 |
RING AND
BALL APPRATUS (ELECTRICAL)
Same as above but supplied with a thermostatic hot plate. Suitable for
operation on 230 V.A.C.
Accessories :Thermometer IP60c range-2 degree celcious x 0.2 degree
celcious.Thermometer IP61c range-30 degree celcious to 300 degree
celcious x 0.2 degree celcious, Electrical Stirrer with stand and blades
to gently stir the water in the beaker. Suitable of operarion on 230 V
A..C. |
|
 |
| |
|
|
|
|
| |
JMT -
103 |
STANDERED PENETROMETER IS :310,1203,1448, IP : 60, 49, 50, ASTM : D5,
D217, D637
Used to determine grade of bitumen. The penetration tests
determinconsistency of bitumen for the purpose of grading. Depth is
units 1/10 of millimeter to which a standered needel having a standered
weight will penetrate vertically in a duration of five seconds at a
temprature of 25 degree celcious determines penetration of gradation.
Specifications : It consists of a vertical pillar mounted on a base
provided with levelling screws. The head, together with dial plunger rod
and cone (or needel) slides on a pillar and can be clamped at any
desired height. A rack and pinion and pointer assembel provides fine
adjustment of needel or cone tip to sample. It incorporates a cluch
mechanisum which makes reading of penetration and subsequent resetting a
simple and accurate operation. The dial is graduated in 400 1/10 and the
millimeter subdivision and the needle pointer against figures makes easy
reading. Supplied with a bitumen penetration needle, ring weight one
each 50 gms, and two sample containers.
Accessories : Penetration cone for empirical estimation of
penetration of lubricating grease, petroleum jelly etc. |
|
 |
| |
|
|
|
|
| |
JMT -
104 |
AUTOMATIC STANDARD PENETROMETER
Same as above but supplied with transistorised timer and electro-magnet
incorporated in the cluch mechanisum to accurately control penetration
time to exact five five seconds. |
|
 |
| |
|
|
|
|
| |
JMT -
105 |
DUCTILITY TESTING APPRATUS
IS : 1028 - 1958, ASTM : D113, IP 32,55.
In flexible pavement construction, bitumen binders are used. It is
important that bituminous material forms ductile thin film around the
aggregates, which serves as a binder. The binder materialness of
sufficient ductility renders pervious pavement surface and leads to
development of cracks. Therefore it is important to carry out the
ductility tests on betumenus material. Ductility is defined as distance
in cms to which a standard briquette to bitumen can be stretched before
the thread breaks. The briquette is streched at a rate of 50mm/minute
+/-2.5 mm per minute at a temprature of 27 degree celcious +/-0.5 degree
celcious.
Specifications : The apparatus consists of a water bath with a
thermostatic heater, and a circulating pump to maintain uniform water
temperature. One half of the briquette mouldsis fixed on a fixed palate
in the water bath, the other half of the briquette mould is fixed to a
carrier which slides over a rotating thread shaft with a cluch. The
motor or gears to rotate the shaft are housed in a cabinet fixed above
the other end of the bath. A pointer fixed to the carrier moves over a
scale graduated to 0 - 110cm x 1mm fixed on the bath with "0"(zero) of
the scale towards the fixed plate slide. The rotating shaft has 2 speeds
of travel for the bracket,5 cm/min.and1cm/min.,
selected by a cluch. Water bath is provided with a drain. A heater with
thermostatic control is fixed inside the water bath. Control switches
for motor, stirer, heater indicator lamps are fixed at a convenient
place on the water bath, Completer with the three briquette moulds and
one base plate, all made of brass. operates on 230 volts A.C., single
phase.
Accessories : 1.Thermometer IP 38 c, range 23 degree celcious to
27 degree celcious 2. Ductility mould with base plate. |
|
 |
| |
|
|
|
|
| |
JMT -
106
|
STRIPPING
VALUE APPARATUS
For
determining Stripping value of bitumenous mixes having aggregate size
1.0 mm to 75 microns.
Specifications :A circular tray rotates in a vertical plane at a rate
of approximately 100 r.p.m. by an electrical geared motor. 4 bottles
of approximately 400 cc are mounted on this circular tray at an angle of
90 degree to each with their mouth towards center of the tray. A time
switch is provided.Suitable for operation on 230 volts A.C. single
phase.
|
|
 |
| |
|
|
|
|
| |
JMT -
107 |
BENKLEMAN
BEAM
This device was developed by U.S. Bureau of Public Roads and is used to
measure deflection of flexible pavements. The light weight instrument is
supplied in two parts for assembling on site with easy hand tools. In
use one end of the beam rests at a point under investigation while the
beam is pivoted at the center. The free end carries a dial gauge to
record the deflections. The other end is kept on a stable platform. The
beam ratio is 2:1 which nagnifies even small deflections. Supplied with
a dial guage 0.01x25mm. This is a light weight dismantleable instrument
and easy to carry. |
|
 |
| |
|
|
|
|
| |
JMT -
108 |
CENTRIFUGE EXTRACTOR(HAND OPERATED)
ASTM : D2172, AASHO: T-58, T-164.
This instrument is used for determination and checking of bitumen
percentage in bitumenous mix, the mix is added with a solvent and
dissolved bitumen is removed by centrifugal action. Consists of a
removal aluminium rotor bowl, capacity 1500gms. with a cap and
tightening nut. The bowl assembly is mounted on a vertical shaft which
protrudes from a cast housing. This shaft and thus the bowl is rotated
fast manually by enclosed gears in the cast body and handle. Solvent is
introduced during the test through the holes in the cap of the housing.
a drain is provided to collect dissolved bitumen coming out of the
rotating bowl and getting collected in the housing. |
|
 |
| |
|
|
|
|
| |
JMT -
109 |
CENTIFUGE EXTRACTOR(MOTORISED)
Same as above but shaft is rotated by an electric motor and gear. Care
is taken to prevent solvent entering into the rorot of elecrical
motor. Operates on 230 volts A.C. single phase.
Accessories :
1. Filter paper disc.(packet of 100 nos.)
2. Benzene
|
|
 |
| |
|
|
|
|
| |
JMT -
110 |
MARSHALL STABILITY TEST APPRATUS
ASTM : D 1559 - T - 62
Originally devoloped by Brause Marshall, a highway engineer in U.S.A.
later on standerdised by ASTM. Generally the test is applicable to hot
mix designs using bitumen and aggregates upto a maximum size of 25 mm.
In this meatheod, the resistance to plastic deformation of cylindrical
specimen of bitumenous mixture is measured when the same is loaded at
periphery at 5 cm per min. This test procedure is used in designing and
evaluating bitumenous paving mixes.The test procedures is extensively
used in routine test programmes for paving jobs.There are two major
features of the marshall meatheod of designing mixes namely.
a) Density - voids analysis b)Stability - flow tests.
The marshall stability of mix is defined as a maximum load carried by a
compacted specimen at a standered test temprature of 60 degree celcious.
The flow value is deformation the marshall test specimen under goes
during the loading upto the maximum load, in 0.25mm units.In this test
and attempt is made to determine optimum binder content for the type of
aggregate mix and traffic intensity.
The appratus consists of :
1)A Loading unit motorised, capacity 5000kgf with two telescopic
pillars and an adjustable cross head. Limit switches are fitted inside
to control upwards and downwards movement of the pillars.On-off
reversing switch and indicator lamps are on the front side while a hand
wheel to manually move the pillarsis on the right. The load frame has
fixed speed of 5.08cm, per minute.Operated on 230 volts A.C.
2)1 no. Compaction pedal with specimen mould holder.
3)2 no. Compaction Rammers,4.5 kg weight and free fall
45.7cm.
4)1 no. Breaking head assembly with provision to fix
flowmeter.
5)3 no. Specimen mould 10.16cm I.D. x 7.6cm heigh with
base plateand extension collar.
6)1 no. Kit for specimen extraction, consists of one each
load transfer bar, steel ball, specimen extracting plate.
Accessories :
(A) integral type proving ring capacity 3000kgs.
(B) A dial gauge 0.01x25mm.
(C) Universal water bath S.S. with ffalse bottom and pyramid
shaped lid to accomodates 3 Nos. Marshall specimens.
(D) Thermometer 0 - 250 degree celcious x 1 degree celcious
|
|
 |
| |
|
|
|
|
| |
Bitumen |
Asphalt |
Aggregate |
Cement Concrete |
Soil |
|